cost efficiency

standardized accuracy

workflow fit

OR visibility

simple, reliable use

Hospital Integration

Zero Setup

Ready Out of the Box. Drop in a sterile tip and go.

No calibration, no digital overlays, no special microscopes required. Robomarker G2 is ready for immediate use in any pre-op workflow.

Fits Seamlessly into Existing Workflow

Enhances efficiency, not complexity.

Designed to integrate into your current preoperative process. Marks are applied while the patient is upright, saving time in the OR.

Safe & Regulatory-Friendly

Sterile, single-use tips minimize infection risk.

The handle never touches the eye, and pre-inked Robotips are fully disposable and pre-sterilized, reducing cross-contamination and TASS risk.

Durable, High Contrast Marks

Precision that lasts for the duration of surgery.

The proprietary ink holds for over two hours, ensuring consistent, reliable marking for accurate surgical alignment.

Demonstration: RoboMarker® G2 marks remained visible through multiple irrigation cycles. Watch Video Here

Low Maintenance

Insert, mark, dispose — minimal overhead.

Robomarker G2 uses pre-sterilized, single-use Robotips. Simply insert a new tip, make the mark, and discard the used tip. The handle never touches the eye and requires no cleaning, sterilization, or maintenance, freeing OR and supply staff while maintaining surgical precision.

Time-Saving in the OR

Save valuable surgical minutes.

By marking preoperatively and avoiding remarking under the microscope, Robomarker G2 streamlines your surgical flow and reduces OR time.

3 Simple Steps

Step 1

Insert and Align RoboTip

Attach RoboTip G2 to handpiece; press rear button to light axis dial. Rotate RoboTip G2 to desired axis.

Step 2

Turn on Laser

Press rear button for laser projection (laser will blink or turn off if held out of level). Align patient’s head.

Step 3

Mark Patient

Have patient look at light. Use rotary brake if needed. Hold RoboTip on cornea for 1 second.

Regulatory Status

RoboMarker G2

The RoboMarker® is an FDA-regulated Class I, 510(k)-exempt medical device, meaning it meets FDA requirements without needing a premarket submission. As a Class I instrument, it follows all applicable quality, safety, and labeling standards, giving hospital systems confidence in compliance, sterility, and ease of adoption within existing workflows.

RoboTips G2

RoboTips are also FDA-regulated Class I, 510(k)-exempt medical devices, manufactured under applicable quality, safety, and labeling standards. Their validated sterility and compliant design ensure they integrate seamlessly into hospital infection-control and procurement requirements.

click below to see official FDA product classification ↓

FDA-regulated Class 1, 510(k)-exempt device

*Regulatory documentation, device listing, and sterility validation reports are available upon request for procurement review.

Cost and Procurement

  • Simplified Budgeting: The reusable handle can potentially be classified as non-capital, while the only consumables are pre-sterilized Robotips (~$17 per tip).

  • Low Overhead: Minimal maintenance, no recurring fees, and only consumables to manage.

  • See Your Savings: Curious how Robomarker G2 affects your annual OR efficiency and marking costs?

  • Use our ROI Calculator →

    ✅ ✅ ✅

Calculate Your Savings

*Adjust Values According to Your System





4 min

(Average user reports saving 5 minutes with RoboMarker)






(Cost to sterilize instruments used in traditional marking)






Estimates are based on average U.S. OR costs. Actual results may vary.

Patient Safety and Compliance

  • Reduced Cross-Contamination Risk: Single-use, pre-sterilized tips avoid infection vectors associated with marking pens and reusable marking devices.
  • Improve Quality Assurance/Surgical Case Review Audits: single-use, pre-sterilized, RoboTips avoid TASS, (Toxic Anterior Segment Syndrome) an infection mimic caused by endotoxins on processed reusable corneal markers
  • Streamlined Compliance & Instrument Tracking: The reusable device itself requires no sterilization or autoclaving, simplifying hospital workflow, supporting infection-control protocols, and ensuring easier QA and audit traceability.

Operational Consistency and Outcomes

Consistent, High-Quality Marks: Gravity-based self-leveling mechanism ensures accuracy to within 1° of the chosen axis.


Durable Marking: Proprietary formula remains legible for up to two hours, covering typical surgical prep and procedure times.


Reduced Rework / Reoperation Risk: Consistent, reliable marks reduce the need to re-mark and reduces misalignment/re-operation rates.

Resilient, defined ink marks that last 2+ hours. Pictured here after 26 irrigation washes.

Watch Video Here

Training and Onboarding

  • Rapid Adoption: Intuitive design allows OR staff to start using Robomarker G2 immediately.
  • Minimal Disruption: No complex calibration or software training required––no internet? no problem!

What surgeons are saying

Brandon D Ayres, MDWills Eye Hospital

"The marks generated by the RoboMarker completely overlaid what the ORA told us to do. We can trust the marks at least as much as we can trust our formulas."

Jennifer Loh, MDLoh Ophthalmology

“I love how the RoboMarker’s balance weight system ensures precise alignment and accurate marking of the astigmatism axis, no matter my hand position. The built-in patient fixation light and pre-inked marking tips make the entire process simple, reliable, and highly efficient.”

James Murphy, MDScarsdale Ophthalmology

"Saves me valuable time in the OR / prep area!"

Neel Desai, MDThe Eye Institute of West Florida

"The RoboMarker is accurate and intuitive. I have used the original for several years as a backup for toric alignment, but as I've become presbyopic, I appreciate the new and improved lighted marker. I also love the adjustable diameter on the marker tips--useful for toric alignment but also transcleral IOL fixation to mark outside the limbus. What a wonderful, simple, and elegantly designed device to have."

Tate Saurey, MDWaynesborough Ophthalmology

"I've been using the RoboMarker system for several years, and the G2 version is a standout upgrade. It's an excellent tool for astigmatism correction —accurate, efficient, and it streamlines surgical workflow. The built-in level indicator ensures precise corneal markings, and the new stop button is a smart feature that prevents pivoting if both arms don't contact the cornea simultaneously. Overall, it's a well-engineered device that continues to add significant value in cataract and refractive surgery."

Madeline Hay, MD

"Fantastic piece of equipment! Thank you!"

Annie Yan, MD

"We love using the RoboMarker at the VA — makes it very easy to mark our patients preoperatively. Fast and simple — easy to learn."

Cindy Volpe, MDPalmetto Surgery Center

"Love the new RoboMarker––especially the new lighted / magnified dial with better marking ink!"

180°

of Alignment

10min

or less to train

3-5min

Average time saved per case

800,000+

Surgeries Performed

The Nation's Best Trust RoboMarker

Clinical Validation and Adoption

Exceptional care demands exceptional products. We are honored to have RoboMarker products pre-approved for use in the best hospitals in the nation.

The RoboMarker System consistently delivers precise, long-lasting corneal marks that enhance the accuracy of toric IOL alignment, reducing intraoperative errors and improving visual outcomes. Its streamlined marking process contributes to greater surgical efficiency, supporting better patient safety and predictable refractive results in ophthalmic surgery.

Not listed? Contact us today!